Alarm List
Alarm Number (4000 to 4999)
Alarm List-491
other If the alarm occurs again, save the CMOS.BIN in maintenance mode, 
and then contact your Yaskawa representative about occurrence 
status (operating procedure).
11 The error on getting of server 
address occurred in the SNTP 
process of the Ethernet 
function.
Setting error (1)Check the following settings.
∙ The DHCP server operation
∙ The network status
YCP21 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YCP21 board. Save the 
CMOS.BIN before replace the board to be safe. Replace the YCP21 
board, and then insert the CF card which inserted original YCP21 
board into the new YCP21 board. 
other If the alarm occurs again, save the CMOS.BIN in maintenance mode, 
and then contact your Yaskawa representative about occurrence 
status (operating procedure).
12 The server setting is incorrect 
in the SNTP process of the 
Ethernet function (for future 
use).
Setting error (1)Check the following settings.
∙ SNTP setting
YCP21 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YCP21 board. Save the 
CMOS.BIN before replace the board to be safe. Replace the YCP21 
board, and then insert the CF card which inserted original YCP21 
board into the new YCP21 board. 
other If the alarm occurs again, save the CMOS.BIN in maintenance mode, 
and then contact your Yaskawa representative about occurrence 
status (operating procedure).
4144 FUNCTION 
EXECUTION ERROR
0 FN591 was executed 11 or 
more times in a row.
Teaching failure (1)Reset the alarm. 
(2)Don't set FN593 11 or more times in a row. Review the teaching.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode, 
and then contact your Yaskawa representative about occurrence 
status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy