Alarm List
Alarm Number (4000 to 4999)
Alarm List-753
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
9 An error occurred in conveyor
characteristic file number
check.
Setting error (1)Check the following settings.
∙ Confirm that the specified conveyor condition file number is 1 to 6.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
10 An error occurred in press
characteristic file number
check.
Setting error (1)Check the following settings.
∙ Confirm that the specified press characteristic file number is 0 to 3.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
12 An error occurred in conveyor
calibration file number check.
Setting error (1)Check the following settings.
∙ Confirm that the specified conveyor calibration file number is 1 to 6.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
13 An error occurred in argument
number check.
Setting error (1)Check the following settings.
∙ Confirm that the argument number is 1 to 16.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
14 An error occurred in check for
motor gun characteristic file
number.
Setting error (1)Check the following settings.
∙ Confirm that the specified servo gun characteristic file number is 1 to
24.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4451 UNDEFINED
REFERENCE POINT
Sub Code: Reference point
number in binary
Setting error (1)Check the following settings.
∙ Set the reference point.
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy