Alarm List
Alarm Number (4000 to 4999)
Alarm List-754
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4452 STACK MORE THAN
10 (JOB CALL)
Setting error (1)Check the following settings.
∙ Change the job configuration so that the number of nests for CALL
instruction is twelve or less.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4453 OVER VARIABLE NO. The variable number is out of
range.
Sub Code: The variable
number which an attempt was
made to use
Setting error (1)Check the following settings.
∙ Correct the job using the variable number within the range.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4454 UNDEFINED POWER
SOURCE COND.
Setting error (1)Check the following settings.
∙ Complete the settings for the arc welding characteristic file.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4455 UNDEFINED ARC
START COND FILE
Setting error (1)Check the following settings.
∙ Complete the settings for the welding start condition file.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4456 UNDEFINED ARC
END COND FILE
Setting error (1)Check the following settings.
∙ Complete the settings for the welding end condition file.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy