13 Trouble Shooting When Alarm is not Displayed
13-7
WindowsCE
screen
‘P’ The programming
pendant is out of order
or malfunctions.
IP address
or subnet
mask
specification
failure
The IP address or subnet mask of
programming pendant may be wrong.
Confirm and specify the IP address or
subnet mask. The followings are the
confirmation procedure.
(1)Turn ON the power while pressing
”interlock+9+select”.
(2)After bleeping, leave hand.
(3)After the message “Start was
canceled” is displayed, press the OK
button at the upper right.
(4)Touch the lower left of screen with the
pen to display the task bar and select
START.
(5)After the start menu is displayed,
select [Settings] [Control Panel]
[Network and Dial-up Connections]
[SMSC911X17].
(6)IP address specification screen is
displayed and then confirm the
followings are set.
IP Address 10. 0. 0. 4.
Subnet Mask 255.255.255. 0
Default Gateway . . .
Also, confirm that Specify an IP
address is ticked.
Data failure The file stored in the programming
pendant is not in the specified area.
Perform “chapter3 Programming
Pendant Setup” of the DX200 SETUP
PROCEDURE MANUAL.
Controller<-
>Pendant
Connection Failed.
The power supply is
not provided from the
YPS power supply unit
to the programming
pendant.
Cable
failure
(1) Turn the power OFF then back ON
(2) If the error occurs again, check the
connection and insertion status of the
following cables and connectors.
a)The looseness of the programming
pendant connector and confirmation
by touch.
b)The cable between the YCP21 circuit
board(CN105) and the programming
pendant
c)The Ethernet cable of YCP21 circuit
board(CN105)
d)The connector of YCP21 circuit
board(CN105)
The programming
pendant is out of order
or malfunctions.
Programming
pendant
failure
(1) Turn the power OFF then back ON
(2) If the error occurs again, replace the
programming pendant.
Screen status of
programming
pendant
7SEG
LED for
robot I/F
circuit
board
(YIF)
Assumed status Cause Remedy

Table of Contents

Other manuals for YASKAWA DX200

Related product manuals