Alarm List
Alarm Number (4000 to 4999)
Alarm List-709
GND wiring failure (1)Turn the power OFF then back ON.
(2) If the alarm repeats, check the voltage of the primary power and
GND. If the voltage amount on each RST varies more than 100V,
review the GND setting.
Module failure (motor) (1)Reset the alarm.
(2)If the alarm occurs again, replace the motor.
Module failure (amplifier) (1)Reset the alarm.
(2)If the alarm occurs again, replace the amplifier.
Module failure (contactor) (1)Reset the alarm.
(2)If the alarm occurs again, replace the contactor.
EAXA21 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the EAXA21 board. Save the
CMOS.BIN before replacing the board to be safe.
YPU unit failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YSF21 board. Save the
CMOS.BIN before replacing the YPU unit to be safe.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4336 OPEN PHASE
(CONVERTER)
Sub Code: Signifies the
physical No. of converter in
which the alarm occurred
Connection failure (1)Reset the alarm.
(2)If the alarm occurs again, check the connection and inserting state
of the following cables and connectors.
EAXA21-CN507,510
EAXB21-CN531,532,533
Converter CN551,553
EX1SV (External axis SERVO PACK)-CN591, CN592
Voltage failure Modify the primary breaker voltage to the specified voltage
200V(+10% to 15%).
YPU unit failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YSF21 board. Save the
CMOS.BIN before replacing the YPU unit to be safe.
Module failure (converter) (1)Reset the alarm.
(2)If the alarm occurs again, replace the converter.
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy

Table of Contents