Alarm List
Alarm Number (1000 to 1999)
Alarm List-308
1330 MICRO PROGRAM
TRANSMIT ERROR
Sub Code: Signifies the axis
in which the alarm occurred
EAXA21 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the EAXA21 board. Save the
CMOS.BIN before replace the board to be safe.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
1331 CONVERTER
CHARGE
ERR(CONVERTER)
Connection failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connection and insertion of the
following cables and connectors.
EAXA21-CN507,510
EAXB21-CN531,532,533
Converter CN551,553
EX1SV(External axis servo pack)-CN591,592
Primary power failure Check if the primary power supply voltage does not drop.
Module failure (converter) (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the converter.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
1332 POSITION ERROR EAXA21 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the EAXA21 board. Save the
CMOS.BIN before replace the board to be safe.
Check the position after the alarm.
Connection failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connection and insertion of the
following cables and connectors.
[Robot axis]
Cable between encoders
EAXA21-CN508
[External axis]
Cable between encoders
EAXB21-CN0534,535,536
Alarm
Number
Alarm Name Sub
Code
Meaning Cause Remedy

Table of Contents