3 Inspections
3.1 Regular Inspections
3-1
3 Inspections
3.1 Regular Inspections
Carry out the following inspections.
CAUTION
Do not touch the cooling fan or other equipment while the
power is turned ON.
Failure to observe this caution may result in electric shock or injury.
Inspection
Equipment
Inspection Item Inspection
Frequency
Comments
DX200 Controller Check that the doors
are completely
closed
Daily
Check for gaps or
damage to the
sealed construction
Monthly
Interior circulation
fan, backside duct
fan and fan for the
heat exchanger
Check operation As required While power ON
Emergency stop
button
Check operation As required While servo ON
Enable switch Check operation As required In teach mode
Battery Confirm battery
alarm or message is
displayed or not
As required
Power Supply Check power supply
voltage is normal
As required
Circuit Breaker
Lead Cables
Check falling out,
loosing or breaking
of the lead cables
Check the correlate
voltage
As required