Alarm List
Alarm Number (4000 to 4999)
Alarm List-821
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
5 The control group in the
memory play file did not agree
with the control group of
execution job.
Setting error (1)Check the following settings.
Check the control group setting of the used memory play file.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
6 An attempt was made to clear
the memory play file by a
CLEAR instruction before
having executed a MEMOF
instruction.
Setting error (1)Check the following settings.
Execute the MEMOF instruction, and then execute the CLEAR
instruction.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4610 MEMOPLAY
SAMPLING ERROR
1 Failed to read the memory
play sampling data.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
2 Failed to write the memory
play sampling data.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
3 Failed to seek the memory
play sampling data.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
4 Failed to read the memory
play file.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy