4546 CANNOT EXECUTE
SYSTEM JOB
Sub Code: System number Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
4547 PRIMITIVE ERROR Sub Code: Error code Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
4548 CANNOT OPERATE
SPECIFIED EVENT
Sub Code: System number Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
4549 NOT EXECUTION OF
INIEVNT
Sub Code: System number Setting error (1)Check the following settings.
Execute an INIEVNT instruction before executing an event related
instruction.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4550 CANNOT EXECUTE
INST(USER JOB)
Sub Code: System number Setting error (1)Check the following settings.
This instruction cannot be executed in the system job. Correct the job
so that the instruction is executed in the user job.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4551 CANNOT MEASURE
TIP INSTALL COEF
Sub Code: Gun number Setting error (1)Check the following settings.
Execute the "SVGUNCL TWC-AE", and then execute the "SVGUNCL
TWC=BE".
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4565 SOFTWARE
UNMATCH
1 The multi-layer welding
function is not used.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy