Alarm List
Alarm Number (4000 to 4999)
Alarm List-803
5 Position data error Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
6 Setting error of the slave
group for user coordinate
conversion
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
4567 CANNOT MONITOR
DISTANCE
Setting error (1)Check the following settings.
∙ Change the interpolation instruction to MOVL/MOVC.
∙ Change the setting so that the arc retry or restart operation does not
perform.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4568 UNDEFINED PRESS
COND DATA FILE
Sub Code: Press
characteristic file number
Setting error (1)Check the following settings.
∙Set the status of press characteristic file to be used in the job to "Used
State."
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4569 UNDEFINED PRESS
RESOLUTION DATA
Sub Code: Press
characteristic file number
Setting error (1)Check the following settings.
∙ Set the press resolution data to be used in the job.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4571 SERVO FLOAT MODE
RELEASE ERR
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
4572 NO SERVO GUN
CONTROL GROUP
Setting error (1)Check the following settings.
∙ Set the "motor gun axis" in the control group setting of maintenance
mode.
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy