12 Program Upload Function
12.4 Restoration Procedure 2 (Loading the Batch Data)
12-8
– When the message "Loading system data. Don't turn the power off."
on the human interface display area disappears, loading is
completed.
12.4.2 When the Batch Data is "CMOSBK.BIN"
When the batch data is "CMOSBK.BIN (or "CMOSBK??.BIN: ??
represents a number")”, write the data as shown below.
1. Turn ON the DX200 while pressing down the [MAIN MENU].
– The maintenance mode starts.
2. Set the security mode to the one time manage mode.
3. Select {EX. MEMORY} under the main menu.
– The sub menu appears.
4. Select {SYSTEM RESTORATION}.
– The backup file list window appears.
5. Select a date of a file to be backed-up.
– The confirmation dialogue box to confirm whether the board has
been replaced or not appears.
– Select {YES} to initializes “SYS MONITORING TIME”.
– Select {NO} to keep “SYS MONITORING TIME” unchanged.