Alarm List
Alarm Number (0000 to 0999)
Alarm List-155
3 In the output side setting of
allocation configuration data,
the specified
R-register start No. for the
TOYOPUC exceeds the R-
register limit.
Setting error (1)Check the following settings.
∙ Allocation configuration for the TOYOPUC
Connection failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connection and insertion of the
following connector.
∙ The PCI connector of the TOYOPUC board
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4 In the output side setting of
allocation configuration data,
the set number to use the
input side R-register of the
TOYOPUC exceeds the R-
register limit.
Setting error (1)Check the following settings.
∙ Allocation configuration for the TOYOPUC
Connection failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connection and insertion of the
following connector.
∙ The PCI connector of the TOYOPUC board
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
5 In the output side setting of
allocation configuration data,
the set number to use the M-
register of concurrent I/O
exceeds the M-register limit.
Setting error (1)Check the following settings.
∙ Allocation configuration for the TOYOPUC
Connection failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connection and insertion of the
following connector.
∙ The PCI connector of the TOYOPUC board
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy