Alarm List
Alarm Number (1000 to 1999)
Alarm List-311
Module failure (converter) (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the converter.
EAXA21 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the EAXA21 board. Save the
CMOS.BIN before replace the board to be safe.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
103 Transmission buffer FULL
(The first digit shows the
converter No.)
Connection failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connection and insertion of the
following cables and connectors.
∙ EAXA21-CN507,510
∙ EAXB21-CN531,532,533
∙ Converter-CN551,553
∙ EX1SV(External axis servo pack)-CN591,592
Module failure (converter) (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the converter.
EAXA21 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the EAXA21 board. Save the
CMOS.BIN before replace the board to be safe.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
104 CRC-16 failure (The first digit
shows the converter No.)
Connection failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connection and insertion of the
following cables and connectors.
∙ EAXA21-CN507,510
∙ EAXB21-CN531,532,533
∙ Converter-CN551,553
∙ EX1SV(External axis servo pack)-CN591,592
Module failure (converter) (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the converter.
Alarm
Number
Alarm Name Sub
Code
Meaning Cause Remedy