Alarm List
Alarm Number (1000 to 1999)
Alarm List-328
1345 SAFE CIRCUIT
SIGNAL NOT
SAME(SV)
Sub Code: XYY (Signifies the
power-ON unit No. and
unmatched signal No.)
X: Power-ON unit
0: Power-ON unit1 (TU#1)
1: Power-ON unit2 (TU#2)
2: Power-ON unit3 (TU#3)
3: Power-ON unit4 (TU#4)
4: Power-ON unit5 (TU#5)
5: Power-ON unit6 (TU#6)
YY: Unmatched signal
01: KMMA signal unmatched
error
02: SVMAIN signal
unmatched error
03: SVMAIN1/2 signal
unmatched error
04: IORDY signal unmatched
error
05: ONEN signal unmatched
error
06: FUCUT signal unmatched
error
07: SHOCK1 signal
unmatched error
08: EXOT signal unmatched
error
09: OT signal unmatched
error
10: TUSONER signal
unmatched error
11: SVCMPER signal
unmatched error
Connection failure Check if the unmatched two double-checked signals are in agreement.
Alarm
Number
Alarm Name Sub
Code
Meaning Cause Remedy