Alarm List
Alarm Number (1000 to 1999)
Alarm List-372
1863 M-SAF SETUP
ERROR
1 The parameter setting is
incorrect.
Setting error Please re-configure the setting of the control group in maintenance
mode.
YSF21 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YSF21 board.
Other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
2 Parameter setting does not
match the number of YSF22
boards.
Setting error In maintenance mode, check that the control group setting is
appropriate for the system.
YSF22 board failure Check the rotary switch setting of YSF22 board.
YSF21 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YSF21 board.
Other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
3 The parameter setting is
incorrect.
Setting error In the control group setting window of maintenance mode, check that
the following items are appropriate for the system configuration.
(1)In case of STO connection:
-Servo board which connects to each control group
-The number of axis which connects to connector of each servo board
-Contactor unit which connects the brake
-Converter which connects the axis
-ON_ENABLE signal which connects to each control group
-The setting of overrun signal
(2)In case of Contactor connection:
-Servo board which connects to each control group.
-The number of axis which connects to connector of each servo board
-Axis number to be connected to the connector of the servo board
-Converter which connects the axis
-Contactor unit which connects the brake
-The setting of overrun signal
YSF21 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YSF21 board.
Alarm
Number
Alarm Name Sub
Code
Meaning Cause Remedy