Alarm List
Alarm Number (4000 to 4999)
Alarm List-437
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4062 MEMORY ERROR
(LNR SCALE FILE)
Sub Code: File number Data error (1)Reset the alarm.
(2)If the alarm occurs again, initialize the linear scale condition file in
maintenance mode, and then load the linear scale condition file saved
in the external memory device.
YCP21 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YCP21 board. Save the
CMOS.BIN before replace the board to be safe. Replace the YCP21
board, and then insert the CF card which inserted original YCP21
board into the new YCP21 board.
YIF01 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YIF01 board. Save the
CMOS.BIN before replace the board to be safe. Replace the YIF01
board, and then load the CMOS.BIN saved before alarm occurred.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4063 MEMORY ERR
(CONVEYOR COND
SUPP.)
Sub Code: File number Data error (1)Reset the alarm.
(2)If the alarm occurs again, initialize the conveyor condition auxiliary
file in maintenance mode, and then load the conveyor condition
auxiliary file saved in the external memory device.
YCP21 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YCP21 board. Save the
CMOS.BIN before replace the board to be safe. Replace the YCP21
board, and then insert the CF card which inserted original YCP21
board into the new YCP21 board.
YIF01 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YIF01 board. Save the
CMOS.BIN before replace the board to be safe. Replace the YIF01
board, and then load the CMOS.BIN saved before alarm occurred.