Alarm List
Alarm Number (4000 to 4999)
Alarm List-457
7 Illegal data received Setting error (1)Reset the alarm.
(2)If the alarm occurs again, send EOT code to release the data link
and then check that the sending side data is correctly set.
(3)Check that the communication setting is correct.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4114 TRANSMISSION
HARDWARE ERROR
1 Overrun error Communication error (1)Reset the alarm.
(2)If the alarm occurs again, check the communication setting and
communication wiring is correct.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
2 Parity error Communication error (1)Reset the alarm.
(2)If the alarm occurs again, check the communication setting and
communication wiring is correct.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
3 Framing error Communication error (1)Reset the alarm.
(2)If the alarm occurs again, check the communication setting and
communication wiring is correct.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4 Transmission timeout
(timer A)
Communication error (1)Reset the alarm.
(2)If the alarm occurs again, check the communication setting and
communication wiring is correct.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
5 Transmission timeout
(timer B)
Communication error (1)Reset the alarm.
(2)If the alarm occurs again, check the communication setting and
communication wiring is correct.
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy