Alarm List
Alarm Number (4000 to 4999)
Alarm List-529
4 A job was newly created with
the same name of the job
already specified in the
memory.
Software operation error
occurred
(1)Reset the alarm.
(2)If the error occurs again, delete the job where the alarm occurred.
(3)If the error occurs again after the previous measures were
executed, initialize the job file in the maintenance mode, and then load
the saved job file.
(4)If the error occurs again though the previous measures were
executed, save the CMOS.BIN in maintenance mode, and then contact
your Yaskawa representative about occurrence status (operating
procedure).
5 A job was newly created with
the same name of the job
already specified in the
memory.
Software operation error
occurred
(1)Reset the alarm.
(2)If the error occurs again, delete the job where the alarm occurred.
(3)If the error occurs again after the previous measures were
executed, initialize the job file in the maintenance mode, and then load
the saved job file.
(4)If the error occurs again though the previous measures were
executed, save the CMOS.BIN in maintenance mode, and then contact
your Yaskawa representative about occurrence status (operating
procedure).
6 The allowable job registration
area (memory) was
exceeded.
Software operation error
occurred
(1)Reset the alarm.
(2)If the error occurs again, delete unused jobs.
(3)If the error occurs again after the previous measures were
executed, initialize the job file in the maintenance mode, and then load
the saved job file. In that case, delete the unused jobs.
(4)If the error occurs again though the previous measures were
executed, save the CMOS.BIN in maintenance mode, and then contact
your Yaskawa representative about occurrence status (operating
procedure).
7 A job that did not exist in the
memory was specified.
Software operation error
occurred
(1)Reset the alarm.
(2)If the error occurs again, delete the job where the alarm occurred.
(3)If the error occurs again after the previous measures were
executed, initialize the job file in the maintenance mode, and then load
the saved job file.
(4)If the error occurs again though the previous measures were
executed, save the CMOS.BIN in maintenance mode, and then contact
your Yaskawa representative about occurrence status (operating
procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy

Table of Contents