Alarm List
Alarm Number (4000 to 4999)
Alarm List-532
14 There was an instruction that
did not exist in a job because
of inconsistency of the system
software.
Software operation error
occurred
(1)Reset the alarm.
(2)If the error occurs again, delete the job where the alarm occurred.
(3)If the error occurs again after the previous measures were
executed, initialize the job file in the maintenance mode, and then load
the saved job file.
(4)If the error occurs again though the previous measures were
executed, save the CMOS.BIN in maintenance mode, and then contact
your Yaskawa representative about occurrence status (operating
procedure).
16 Unused handles were lacking
when an attempt was made to
open a job.
Setting error (1)Check the following settings.
The number of call job stacks
Set the job configuration that decreases the number of call job stacks.
Software operation error
occurred
(1)Reset the alarm.
(2)If the error occurs again, delete the job where the alarm occurred.
(3)If the error occurs again after the previous measures were
executed, initialize the job file in the maintenance mode, and then load
the saved job file.
(4)If the error occurs again though the previous measures were
executed, save the CMOS.BIN in maintenance mode, and then contact
your Yaskawa representative about occurrence status (operating
procedure).
18 The number of instructions
added to a job exceeded
9999.
Setting error (1)Check the following settings.
The number of steps in job
Delete unnecessary instructions in job and add new instructions.
Software operation error
occurred
(1)Reset the alarm.
(2)If the error occurs again, delete the job where the alarm occurred.
(3)If the error occurs again after the previous measures were
executed, initialize the job file in the maintenance mode, and then load
the saved job file.
(4)If the error occurs again though the previous measures were
executed, save the CMOS.BIN in maintenance mode, and then contact
your Yaskawa representative about occurrence status (operating
procedure).
19 The number of steps added to
a job exceeded 9999.
Setting error (1)Check the following settings.
The number of steps in job
Delete unnecessary steps in job and add new steps.
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy