Alarm List
Alarm Number (4000 to 4999)
Alarm List-588
105 The type of output data is
incorrect.
Setting error (1)Reset the alarm.
(2)Check the following settings.
The serial port setting
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4228 WRONG DATA Software operation error
occurred
(1)Reset the alarm, and then execute following operation.
∙Select a sub menu [WRONG DATA LOG] under main menu [SETUP].
∙ Execute "RESTORE" by selecting "UTILITY" from the pull-down
menu.
*Occurrence date changes to restoration date after it is restored.
∙ Turn the power OFF and then ON to check the factor of the
inconsistency 1 and 2, on the data inconsistency screen in
maintenance mode.
The factor 1: Check the position of the corresponding file
The factor 2: Register the position of the corresponding file again
*The factor 3:Just turn the power OFF and then ON again.
(2)If it would not restore, select "RE CHECK" from the pull-down menu.
(3)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
Data error (1) If different axes configuration data is loaded, the system data
becomes incorrect status, which causes this alarm. In this case,
execute the following operations.
∙Select a sub menu [WRONG DATA LOG] under main menu [SETUP].
∙ Select "UTILITY" from the pull-down menu to execute "RESTORE".
∙ Load correct axes configuration data
(2)If it would not restore, select "RE CHECK" from the pull-down menu,
and then load correct axes configuration data.
(3)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy