Alarm List
Alarm Number (4000 to 4999)
Alarm List-612
2 Error from welder 2. Arc welding power source
error
3 Error from welder 3. Arc welding power source
error
4 Error from welder 4. Arc welding power source
error
5 Error from welder 5. Arc welding power source
error
6 Error from welder 6. Arc welding power source
error
7 Error from welder 7. Arc welding power source
error
8 Error from welder 8. Arc welding power source
error
107 Sub code: Error No. from
welder.
Arc welding power source
error
4243 MOTOWELD OUTPUT
OVER-CURRENT
1 Error from welder 1. Arc welding power source
error
Confirm the following content.
(1) Check that the torch cable or power cable is not grounded.
(2)Check that the contact tip does not contact the welding work piece.
(3)Check that the encoder cable is not damaged.
(4)Check if the screws of the connector terminal block are securely
fastened. If the encoder cable is disconnected or the screws are
loosened, the wire feeding speed becomes excessively fast and an
error occurs in the wire feeding amount. Replace the encoder cable or
fasten the screws of the connector terminal block.
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy