Alarm List
Alarm Number (4000 to 4999)
Alarm List-625
6 Error from welder 6. Arc welding power source
error
Check the Node of the each welder power sources and robot
controller.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
7 Error from welder 7. Arc welding power source
error
Check the Node of the each welder power sources and robot
controller.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
8 Error from welder 8. Arc welding power source
error
Check the Node of the each welder power sources and robot
controller.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
402 Sub code: Error No. from
welder.
Arc welding power source
error
Check the Node of the each welder power sources and robot
controller.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4250 MOTOWELD DIGITAL
I/F ERROR
1 Error from welder 1. Arc welding power source
error
Confirm the following content.
(1) LAN cable is not damaged.
(2) Protocol type of the VEW01 is correct. (is MOTOWELD type?)
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
2 Error from welder 2. Arc welding power source
error
Confirm the following content.
(1) LAN cable is not damaged.
(2) Protocol type of the VEW01 is correct. (is MOTOWELD type?)
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy