Alarm List
Alarm Number (4000 to 4999)
Alarm List-676
15 Errtf5
Sub code[15**] shows the
error code of Fronius power
source
15:main error code
**:sub error code
Arc welding power source
error
Check cable tree of temperature sensors.
Confirm the Fronius's manual.
16 Errtf6
Sub code[16**] shows the
error code of Fronius power
source
16:main error code
**:sub error code
Arc welding power source
error
Change BPS pc-board.
Confirm the Fronius's manual.
17 DSPE05
Sub code[17**] shows the
error code of Fronius power
source
17:main error code
**:sub error code
Arc welding power source
error
Update firmware, otherwise change the UST board.
Confirm the Fronius's manual.
18 ErrbPS
Sub code[18**] shows the
error code of Fronius power
source
18:main error code
**:sub error code
Arc welding power source
error
Update firmware, otherwise change the UST board or otherwise
change the BPS board.
Confirm the Fronius's manual.
19 Err IP
Sub code[19**] shows the
error code of Fronius power
source
19:main error code
**:sub error code
Arc welding power source
error
Change the BPS board.
Change the secondary diode.
Change the welding transformer.
Confirm the Fronius's manual.