Alarm List
Alarm Number (4000 to 4999)
Alarm List-684
64 Errtf8
Sub code[64**] shows the
error code of Fronius power
source
64:main error code
**:sub error code
Arc welding power source
error
Change the thermo-sensor of the cooling unit.
Confirm the Fronius's manual.
65 hotH2O
Sub code[65**] shows the
error code of Fronius power
source
65:main error code
**:sub error code
Arc welding power source
error
Cool down the cooling liquid.
Confirm the Fronius's manual.
66 tJo
Sub code[66**] shows the
error code of Fronius power
source
66:main error code
**:sub error code
Arc welding power source
error
Allow the JobMaster torch to cool.
Confirm the Fronius's manual.
67 ErrtJo
Sub code[67**] shows the
error code of Fronius power
source
67:main error code
**:sub error code
Arc welding power source
error
Change JobMaster pc-board.
Confirm the Fronius's manual.
68 Err068
Sub code[68**] shows the
error code of Fronius power
source
68:main error code
**:sub error code
Arc welding power source
error Confirm the Fronius's manual.
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy