EasyManua.ls Logo

YASKAWA DX200 - Page 905

YASKAWA DX200
1166 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Alarm List
Alarm Number (4000 to 4999)
Alarm List-684
64 Errtf8
Sub code[64**] shows the
error code of Fronius power
source
64:main error code
**:sub error code
Arc welding power source
error
Change the thermo-sensor of the cooling unit.
Confirm the Fronius's manual.
65 hotH2O
Sub code[65**] shows the
error code of Fronius power
source
65:main error code
**:sub error code
Arc welding power source
error
Cool down the cooling liquid.
Confirm the Fronius's manual.
66 tJo
Sub code[66**] shows the
error code of Fronius power
source
66:main error code
**:sub error code
Arc welding power source
error
Allow the JobMaster torch to cool.
Confirm the Fronius's manual.
67 ErrtJo
Sub code[67**] shows the
error code of Fronius power
source
67:main error code
**:sub error code
Arc welding power source
error
Change JobMaster pc-board.
Confirm the Fronius's manual.
68 Err068
Sub code[68**] shows the
error code of Fronius power
source
68:main error code
**:sub error code
Arc welding power source
error Confirm the Fronius's manual.
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy

Table of Contents