Alarm List
Alarm Number (4000 to 4999)
Alarm List-765
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4 When "any direction" is set for
the correcting direction, the
reference points (REFP) are
taught on the same point.
Setting error (1)Check the following settings.
∙ Check the settings for the reference points (REFP) so that each point
is different.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
5 Designation error for the
coordinated motion control
axis at the reference point
Setting error (1)Check the following settings.
∙ Match the control group designation of the wall point and weaving
execution.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4492 POSITION
CORRECTION
ERROR
1 Data unmatched between the
correction amount data and
the job data:
The information about the
control groups designated for
the series of jobs, which is
added to the correction
amount data, does not include
the valid control-group for the
job.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
2 Data unmatched between the
correction amount data and
the job data:
The valid control-group
information that is added to
the correction amount data
disagrees with the valid
control-group for the job.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy