Pn300 Speed Reference Input Gain 150 to 3000
0.01V
/ rated
speed
600 Immediately Setup
5.3.1
5.5.4
6.9.3
Pn301 Internal Set Speed 1 0 to 10000
1 min
-1
100 Immediately Setup
5.6.1
Pn302 Internal Set Speed 2 0 to 10000
1 min
-1
200 Immediately Setup
Pn303 Internal Set Speed 3 0 to 10000
1 min
-1
300 Immediately Setup
Pn304 JOG Speed 0 to 10000
1 min
-1
500 Immediately Setup 7.3
Pn305 Soft Start Acceleration Time 0 to 10000 1 ms 0 Immediately Setup
5.3.3
Pn306 Soft Start Deceleration Time 0 to 10000 1 ms 0 Immediately Setup
Pn307 Speed Reference Filter Time Constant 0 to 65535 0.01 ms 40 Immediately Setup 5.3.4
Pn310
Vibration Detection Switch 0000 to 0002 − 0000 Immediately Setup −
Pn311 Vibration Detection Sensibility 50 to 500 1% 100 Immediately Tuning
7.16
Pn312 Vibration Detection Level 0 to 5000
1 min
-1
50 Immediately Tuning
Pn324
Moment of Inertia Calculating Start
Level
0 to 20000 1% 300 Immediately Setup 6.3.2
Pn400 Torque Reference Input Gain 10 to100
0.1 V/
rated
torque
30 Immediately Setup
5.5.1
6.9.2
Pn401
Torque Reference Filter Time Con-
stant
0 to 65535 0.01 ms 100
Immediately Tuning 6.9.6
Pn402 Forward Torque Limit 0 to 800 1% 800 Immediately Setup
5.8.1
Pn403 Reverse Torque Limit 0 to 800 1% 800 Immediately Setup
Pn404 Forward External Torque Limit 0 to 800 1% 100 Immediately Setup
5.8.2
5.8.4
Pn405 Reverse External Torque Limit 0 to 800 1% 100 Immediately Setup
Pn406 Emergency Stop Torque 0 to 800 1% 800 Immediately Setup 5.2.3
Pn407 Speed Limit during Torque Control 0 to 10000
1 min
-1
10000 Immediately Setup 5.5.4
Parameter
No.
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification
Reference
Section
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
(Refer to 7.16.)
0
1
2
No detection.
Outputs warning (A.911) when vibration is detected.
Outputs alarm (A.520) when vibration is detected.
Vibration Detection Selection
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)