Applications
58
Setting the Cradle
The Cradle Utility allows you to manually enter cradle settings. To automatically enter cradle settings, use
the optional Smart Cradle Configuration app (CradleSmartConfig).
Setting the cradle charging rate: Depending on the cradle installation configuration, the store technician
can configure each individual cradle slot to enable/disable fast charge. Each cradle can be configured to
charge its docked terminal at 1A (normal charging mode - default setting) or 1.5A (fast charging mode).
NOTE: The cradle charging rate is retained across firmware upgrades.
1. Tap the Settings tab to set the cradle information.
Figure 17 Cradle Utility - Setting Tab
• Row ID: The cradle row number in the dispenser wall.
• Column ID: The cradle column number in the dispenser wall.
• Wall ID: The number of dispenser wall where the cradle is positioned.
• Read Data: Retrieve setting data from the cradle memory and display on the screen.
• Write Data: Tap this button to program the row/col/wall information onto the cradle. Note that each slot
on the Three Slot Cradle needs to be programmed separately.
• Enable Fast Charge: Enable the cradle to charge the PS20 at a current of 1.5A (default setting is 1A)
• Reset Row: Tap to update the Row ID in the text field to “0” on the application.
• Reset Column: Tap to update the Column ID in the text field to “0” on the application.
• Reset Wall: Tap to update the Wall ID in the text field to “0” on the application.
Performing Cradle Diagnostics
Touch Diagnostic tab to perform the cradle diagnostics:
MC18 Product Reference Guide.book Page 58 Tuesday, June 30, 2020 9:07 PM