Chapter 47 SNMP Configuration
ZyWALL 5/35/70 Series User’s Guide
712
47.2 SNMP Traps
The ZyWALL will send traps to the SNMP manager when any one of the following events
occurs:
Destination Type the IP address of the station to send your SNMP traps to.
When you have completed this menu, press [ENTER] at the prompt “Press [ENTER] to confirm or
[ESC] to cancel” to save your configuration or press [ESC] to cancel and go back to the previous
screen.
Table 250 SNMP Configuration Menu Fields (continued)
FIELD DESCRIPTION
Table 251 SNMP Traps
TRAP # TRAP NAME DESCRIPTION
0 coldStart (defined in RFC-1215) A trap is sent after booting (power on).
1 warmStart (defined in RFC-1215) A trap is sent after booting (software reboot).
4 authenticationFailure (defined in
RFC-1215)
A trap is sent to the manager when receiving any
SNMP get or set requirements with the wrong
community (password).
6 whyReboot (defined in ZYXEL-
MIB)
A trap is sent with the reason of restart before rebooting
when the system is going to restart (warm start).
6a For intentional reboot: A trap is sent with the message "System reboot by
user!" if reboot is done intentionally, (for example,
download new files, CI command "sys reboot", etc.).
6b For fatal error: A trap is sent with the message of the fatal code if the
system reboots because of fatal errors.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ZyXEL Communications 5 Series and is the answer not in the manual?

ZyXEL Communications 5 Series Specifications

General IconGeneral
BrandZyXEL Communications
Model5 Series
CategoryGateway
LanguageEnglish

Related product manuals