Protected terminals | 158
Configuring the radios for protected mode
The MHSB switch does not require any special software. However, the radios connected to the MHSB
switch must be configured to work with the MHSB switch. This sets the alarm outputs and inputs to
function in MHSB mode.
You must configure the interfaces of both radios connected to the MHSB switch identically. To perform
this, you can either connect directly to the radio or use the test mode of the MHSB switch.
IP address setup
Before configuring the link, you must ensure that the two independent links have correctly configured
IP address details.
All four radios in the protected link must be on the same subnet.