Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
6Digital input DI5 (10.2 DI delayed status, bit 4).DI5
7Digital input DI6 (10.2 DI delayed status, bit 5).DI6
10Digital input/output DIO1 (11.2 DIO delayed status, bit
0).
DIO1
11Digital input/output DIO2 (11.2 DIO delayed status, bit
1).
DIO2
See Terms and abbreviations (page 169).Other [bit]
-300.0 % / real32Defines a minimum torque limit for the drive (in percent
of nominal motor torque). See diagram at parameter
30.18 Minimum torque sel.
The limit is effective when
the source selected by 30.18 Minimum torque sel
is 0, or
30.18 is set to Minimum torque 1.
Note: Do not set this parameter to 0% in an attempt
to prevent reverse rotation. In an open-loop application,
that is likely to prevent the motor from stopping
altogether. To prevent reverse rotation, use the
speed/frequency limits in this parameter group, or
parameters 20.23/20.24.
Minimum torque 130.19
- / -Minimum torque limit 1. For scaling, see parameter
46.3.
-1600.0 ... 0.0 %
300.0 % / real32Defines a maximum torque limit for the drive (in
percent of nominal motor torque). See diagram at
parameter 30.18 Minimum torque sel.
The limit is effective when
the source selected by 30.25 Maximum torque sel
is 0, or
30.25 is set to Maximum torque 1.
Maximum torque 130.20
- / -Maximum torque 1. For scaling, see parameter 46.3.0.0 ... 1600.0 %
Minimum torque 2 /
uint32
Defines the source of the minimum torque limit for the
drive (in percent of nominal motor torque) when
the source selected by parameter 30.18 Minimum
torque sel is 1, or
30.18 is set to Minimum torque 2 source
See diagram at 30.18 Minimum torque sel.
Note: Any positive values received from the selected
source are inverted.
Minimum torque 2
source
30.21
0None.Zero
112.12 AI1 scaled value (see page ?).AI1 scaled
212.22 AI2 scaled value (see page ?).AI2 scaled
362 Parameters