Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
- / uint16Activates FPTC-xx thermistor protection modules
installed on the control unit of the drive. Using this
word, it is also possible to suppress the warnings (but
not faults) from each module.
FPTC configuration
word
35.30
1 = Yes: Module installed in slot 1.Module in slot 1b0
1 = Yes: Warnings from the module in slot 1 suppressed.Disable slot 1
warning
b1
1 = Yes: Module installed in slot 2.Module in slot 2b2
1 = Yes: Warnings from the module in slot 2 suppressed.Disable slot 2
warning
b3
1 = Yes: Module installed in slot 3.Module in slot 3b4
1 = Yes: Warnings from the module in slot 3 suppressed.Disable slot 3
warning
b5
Reservedb6…15
1 = 10000h…FFFFh
20 ° / real32Defines the ambient temperature of the motor for the
motor thermal protection model. The unit (°C or °F) is
selected by parameter 96.16 Unit selection.
The motor thermal protection model estimates the
motor temperature on the basis of parameters
35.50…35.55. The motor temperature increases if it
operates in the region above the load curve, and
decreases if it operates in the region below the load
curve.
WARNING!
The model cannot protect the motor if the
motor does not cool properly because of dust,
dirt, etc.
Motor ambient
temperature
35.50
1 = 1 ° / 1 = 1 °Ambient temperature.-60...100 °
Parameters 405