Using an external voltage supply directly on the respective brake
The procedure below details how to release the holding brake of a specific axis by
supplying external voltage directly on the brake.
NoteAction
Make the connection to the current motor
according to the Circuit Diagram.
Every axis has a holding brake built into the
axis motor. This holding brake may be re-
leased by connecting 24VDC power supply
directly to one of the connectors in the motor.
DANGER
When power is connected directly to the
brake cable, the brake will be released imme-
diately when the power is switched on.
This may cause some unexpected robot
movements!
1
See chapter Circuit diagram on page 369.
72 3HAC033453-001 Revision: H
© Copyright 2009-2013 ABB. All rights reserved.
2 Installation and commissioning
2.3.3 Manually releasing the brakes
Continued

Table of Contents