4.4.4 Measuring the play, axis 5
General
After reassembly due to repair work or any other reason, the play in axis 5 and 6
must be checked to ensure the repetition accuracy of the robot positioning. The
procedure for axis 5 is detailed below.
Required equipment
NoteArt. no.Equipment, etc.
Content is defined in sec-
tion Standard tools on
page 341.
-Standard toolkit
3HAB1611-6
Measuring tool, play
(IRB 4600 -60/2.05, -45/2.05, -40/2.55)
3HAB6337-1Measuring tool, play
(IRB 4600 -20/2.50)
These procedures include
references to the tools re-
quired.
Other tools and procedures may be required.
See references to these procedures in the
step-by-step instructions below.
Measurement, axis 5
The procedure below details how to measure the play of axis 5.
Note
The measuring tool and measuring values differ depending on robot version!
InfoAction
DANGER
Turn off all:
• electric power supply
• hydraulic pressure supply
• air pressure supply
to the robot, before entering the robot
working area.
1
Move the robot to calibration position and
turn the axis 4 90°.
2
Art. no. is specified in Required equip-
ment on page 262.
Fit the measuring tool, play to the turning
disk.
3
Continues on next page
262 3HAC033453-001 Revision: H
© Copyright 2009-2013 ABB. All rights reserved.
4 Repair