4 Repair
4.3.5. Replacement of cable harness, axes 1-4 IRB 6640ID
3HAC026876-001 Revision: F244
© Copyright 2007-2010 ABB. All rights reserved.
20. If the connection between the SMB battery and
the SMB unit has been broken, the revolution
counters must now be updated!
Detailed in the Calibration chapter -
section Updating revolution
counters on page 392.
21.
DANGER!
Make sure all safety requirements are met when
performing the first test run. These are further
detailed in the section DANGER - First test run
may cause injury or damage! on page 41.
Action Note
Continued