Securing the axis-6 motor
NoteAction
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot
working area.
1
To release the brakes, connect the 24 VDC
power supply.
2
Connect to connector R2.MP6:
pin 2 = 24V
pin 5 = 0V
Grease: Castrol Molub. Alloy 777-1 NG
xx1500002346
Make sure that there is enough grease on
the splines, before fitting.
If not, apply 1 gram of grease.
3
CAUTION
Whenever parting/mating motor pinion and
hub, the splines may be damaged if excess-
ive force is used.
4
Continues on next page
Product manual - IRB 8700 625
3HAC052853-001 Revision: F
© Copyright 2015-2018 ABB. All rights reserved.
4 Repair
4.7.5 Replacing the axis-6 motor
Continued