EasyManua.ls Logo

ABB IRB 930 - Page 28

ABB IRB 930
606 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Pneumatic or hydraulic related hazards
Note
The pressure in the complete pneumatic or hydraulic systems must be released
before service and maintenance.
All components in the robot system that remain pressurized after switching off
the power to the robot must be marked with clearly visible drain facilities and a
warning sign that indicates the hazard of stored energy.
Loss of pressure in the robot system may cause parts or objects to drop.
Dump valves should be used in case of emergency.
Shot bolts should be used to prevent tools, etc., from falling due to gravity.
All pipes, hoses, and connections have to be inspected regularly for leaks and
damage. Damage must be repaired immediately.
Verify the safety functions
Before the robot system is put into operation, verify that the safety functions are
working as intended and that any remaining hazards identified in the risk
assessment are mitigated to an acceptable level.
28 Product manual - IRB 930
3HAC086009-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
1 Safety
1.4 Safety during installation and commissioning
Continued

Table of Contents

Other manuals for ABB IRB 930

Related product manuals