Disconnecting the connectors for axis-4 motor
NoteAction
xx2300000492
Disconnect the axis-4 motor connectors.
R2.MP4
R2.FB4
1
xx2300000495
Snap loose and remove the female head of the
connectors from the bracket.
Note
The harness are not visible due to the cleanness
requirements of the illustration. They are still ex-
isting inside the cable ferrule in the actual situ-
ation.
2
Removing the outer arm cable ferrule and bracket
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
xx2300000496
Remove the screws on the bracket to the cable
ferrule to release the cable ferrule with cable.
Note
The harness are not visible due to the cleanness
requirements of the illustration. They are still ex-
isting inside the cable ferrule in the actual situ-
ation.
2