Reconnecting the connectors for axis-3 motor
NoteAction
xx2300000494
Insert the female head of the connectors to the
bracket accordingly.
Tip
The mistake proofing measure has been applied
to the connectors, the connectors may be dam-
aged if excessive force is used.
Note
The harness are not visible due to the cleanness
requirements of the illustration. They are still ex-
isting inside the cable ferrule in the actual situ-
ation.
1
xx2300000491
Reconnect the connectors.
• R2.MP3
• R2.FB3
See the number markings on the connectors of
the main harness for help to find the correspond-
ing connector.
DANGER
Make sure that the correct connectors are
matched before reconnecting the connectors.
Otherwise the robot motor may be broken.
2
Route the cabling on the axis-3 motor.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
3
Continues on next page
476 Product manual - IRB 930
3HAC086009-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.7.4 Replacing the axis-4 motor sub-assembly
Continued