NoteArticle numberSpare part
Option 3005-2 Moist dust filter3HAC075737-001Air filter, fine (Polymeric)
Required tools and equipment
NoteArticle numberEquipment
Content is defined in section
Standard toolkit for controller on
page 414.
-Standard toolkit
-ESD protective wrist band
Required documents
NoteArticle numberDocument
3HAC074000-008Circuit diagram - OmniCore
V250XT
Installing the air filter
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 28.
1
xx2100002583
For option 3005-2 Moist dust filter:
Insert the polymeric filter element to the
filter and secure with the metallic line.
2
Continues on next page
Product manual - OmniCore V250XT 147
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
3 Installation and commissioning
3.7.8 Installing the air filter
Continued