Note/IllustrationAction
Screws: Torx, countersunk screw M4x10 (2
pcs)
Secure the internal fan attachment
screws.
3
xx2100001283
Reconnect the internal fan:
• G5.X1-K2.X17
4
xx2100000342
Refit the screws holding the fan as-
sembly.
5
Concluding procedure
Note/IllustrationAction
Closing the door on page 176.Close the door.1
Perform the function tests to verify that
the safety features work properly, see
Function tests on page 166.
2
Product manual - OmniCore V250XT 189
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.2.2.2 Replacing the internal fan
Continued