Specifications
The following describes the cable requirements for the incoming mains connection
to the OmniCore V250XT controller.
DescriptionComponent
Flexible oil resistant rubberCable type
3G x 6 mm
2
or AWG10Cable area
PE1 and PE2 points on X0 (incoming mains connector).Protective earth
Included parts
The following parts are included in the delivery.
QuantityOrder numberPart
13HAC075871-001Connector kit
Procedure
Use the following procedure to fit the connectors.
Note/illustrationAction
Cut the cable to desired length.1
2
1
3
4
4
PE1
3
PE2
1
2
xx2100001258
Description
L11
L22
L33
Not used4
Protective earthPE1
Protective earthPE2
Connect the wires according to the illus-
tration.
2
Tighten the screws to secure the cables.3
Remove screw and washer on top of
contact and insert the ground cable with
cable lug. Secure with washer and
screws.