2–32 SelectSet Avantra Series Control Panel and Operating Guide
Viewing Job Status
Figure 2.22 Job status display. Run Screen (left) and Pause Screen (right).
➀—Current resolution. ➁—Current exposure.
➂—Media past the cutter. ➃—Job counter.
Current Resolution: Displays the imagesetter’s current setting for
resolution.
n The imagesetter changes resolution based on commands embed-
ded in the file that is being imaged or commands downloaded to
the RIP from the front-end computer.
Current Exposure: Displays the current exposure value.
n When the imagesetter changes resolution, it automatically uses
the exposure specified in the Cassette Setup screen for that
resolution.
Media Past the Cutter: The imagesetter displays the amount of media
that has been advanced past the cutter.
Job Counter: The number inside the Display Job History button is the
number of images in the drum and take-up cassette.
n If the imagesetter is imaging a job, this number includes the job
being imaged.
n The counter advances every time a job is started, even if you
abort the job before it is complete.