9 Characteristics and Specifications
Agilent U1602B/U1604B User’s and Service Guide 173
[1] For temperature between 0
o
C to 18
o
C and 28
o
C to 50
o
C , add 0.1% of reading + 0.02% of range
for every degree Celsius.
DIGITAL MULTIMETER SPECIFICATIONS
[1]
± (% of reading + % of range)
Function Range Frequency, Test Current or
Burden Voltage
1 year Tcal ± 5
o
C
DC Voltage 600.0 mV 0.3 + 0.08
6.000 V 0.3 + 0.08
60.00 V 0.3 + 0.08
600.0 V 0.3 + 0.08
AC Voltage 600.0 mV – 600.0 V 50 Hz – 1 kHz 1.0 + 0.2
1 kHz – 30 kHz 3.0 + 0.2
AC+DC Voltage 6.0000 V – 600.0 V 50 Hz – 1 kHz 1.0 + 0.2
1 kHz – 30 kHz 3.0 + 0.2
Resistance 600.0 W 0.5 + 0.2
6.000 kW 0.5 + 0.2
60.00 kW 0.5 + 0.2
600.0 kW 0.5 + 0.2
6.000 MW 0.5 + 0.2
60.00 MW 1.0 + 0.2
Capacitance 60.00 nF 2.0 + 0.2
600.0 nF 2.0 + 0.2
6000 nF 2.0 + 0.2
60.00 μF2.0 + 0.2
300.0 μF2.0 + 0.2
Diode 1.000 V 0.5 mA 2.0 + 0.08

Table of Contents

Other manuals for Agilent Technologies U1602B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies U1602B and is the answer not in the manual?

Agilent Technologies U1602B Specifications

General IconGeneral
BrandAgilent Technologies
ModelU1602B
CategoryTest Equipment
LanguageEnglish

Related product manuals