EasyManua.ls Logo

Akuvox E16C - Unlock by Exit Button by Thedoor

Akuvox E16C
117 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.akuvox.com
E16 Door Phone Administrator Guide
62
Note
DoorNumin the HTTP command above refers to the relay number #1 to be
triggered for the door access.
Parameter Set-up:
Enabled: enable the HTTP command to unlock the function by going to Enable.
Username: enter the user name of the device web interface, forexample, Admin.
Password: enter the password for the HTTP command. For example,12345.
Please refer to the following example:
http://192.168.35.127/fcgi/do?
action=OpenDoor&UserName=admin&Password=12345&DoorNum=1
11.9
Unlock by Exit Button by the Door
When you need to open the door from inside using the exit button installed by the door, you
can configure the access control terminal Input to trigger the relay for the door access. To
configure the configuration on web Access Control > Input > Input interface.
Parameter Set-up:

Table of Contents

Related product manuals