Single Tenant Door Phone
AKUVOX SMART INTERCOM www.akuvox.com
Note:
For E12W, the operation path is Access Control > Card Setting.
15.4.Configure Open Relay via HTTP for Door
Unlock
You can unlock the door remotely without approaching the device physically
for the door access by typing in the created the HTTP command (URL) on the
web browser to trigger the relay when you are not available by the door for
the door access. To do this configuration on web Intercom > Relay interface.
Parameter Set-up:
Enable: enable the HTTP command unlock function by clicking on Enable
field.
User Name: enter the user name of the device web interface, for example
“Admin”.
Password: enter the password for the HTTP command. For example :
“12345”.
Please refer to the following example:
http://192.168.35.127/fcgi/do?action=OpenDoor&UserName=admin&Passw
ord=12345&DoorNum=1