Note:
DoorNum in the HTTP command above refers to the relay number #1
to be triggered for the door access.
For E12W, the operation path is Access Control > Relay.
15.5.Configure Exit Button for Door Unlock
When you need to open the door from inside using the Exit button installed
by the door, you can configure the door phone Input to trigger the relay for
the door access on web Intercom > Input interface.
Parameter set-up:
Input service: Select “ Enable “ to be able to use the Input function.
Trigger Option: Select the trigger options according the actual operation
on the exit button.
Action To Execute: select the method to carry out the action among four
options: FTP, Email, HTTP, TFTP.
Http URL: enter the URL if you select the HTTP to carry out the action.
Action Delay: set up the delay time when the action is carried out. For