Boot Options
Basic System Configuration Guide 205
Console Connection
To establish a console connection, you will need the following:
• An ASCII terminal or a PC running terminal emulation software set to the parameters
shown in the table below.
• A standard serial cable with a male DB9.
To establish a console connection:
Step 1. Connect the terminal to the Console port on the CPM/CFM/CCM using the serial
cable.
Step 2. Power on the terminal.
Step 3. Establish the connection by pressing the <Enter> key a few times on your terminal
keyboard.
Step 4. At the router prompt, enter the login and password.
The default login is admin.
The default password is admin.
Configuring BOF Parameters
The following output displays a BOF configuration on a 7750 SR:
A:ALA-1>bof# show bof
==================================================================
Memory BOF
==================================================================
no autonegotiate
duplex full
speed 100
Table 27: Console Configuration Parameter Values
Parameter Value
Baud Rate 115,200
Data Bits 8
Parity None
Stop Bits 1
Flow Control None