System Management
Basic System Configuration Guide 357
System Alarm Contact Input Commands
alarm-contact-in-power
Syntax alarm-contact-in-power {on | off}
Context config>system
Description This command allows the user to enable a supply of +24V output power on the +24VDC pin of the
Alarm Interface Port of the CPM. When enabled, the power supplied through the +24VDC output pin
can be used as a source voltage for the alarm contact input pins. The +24VDC output can be used to
supply power for monitoring external sensor devices such as cabinet door sensors instead of using an
external power source. If users want to use a separate external power source, they should disable the
supply of power to the +24VDC output pin by using this CLI command.
Default off
Parameters on — turns on power to the +24VDC output pin of the Alarm Interface Port of the CPM
off — turns off power to the +24VDC output pin of the Alarm Interface Port of the CPM
alarm-contact-input
Syntax alarm-contact-input input-pin-number
Context config>system
Description This command provides the context to configure one of four available alarm contact input pins.
Parameters input-pin-number — identifies the alarm contact input pin
Values 1 to 4
clear-alarm-msg
Syntax clear-alarm-msg message-string
no clear-alarm-msg
Context config>system>alarm-contact-input
cflash-id cf1:, cf1-A:,cf1-B:,cf2:,cf2-A:,cf2-B:,cf3:,cf3-A:,cf3-B: