System Command Reference
376 Basic System Configuration Guide
startup-alarm alarm-type — Specifies the alarm that may be sent when this alarm is first created.
If the first sample is greater than or equal to the rising threshold value and startup-alarm is
equal to rising or either, then a single rising threshold crossing event is generated. If the first
sample is less than or equal to the falling threshold value and startup-alarm is equal to falling
or either, a single falling threshold crossing event is generated.
Default either
Values rising, falling, either
Configuration example
memory-use-warn rising-threshold 500000 falling-threshold 400000 interval 800 rmon-
event-type log start-alarm falling
rmon
Syntax rmon
Context config>system>thresholds
Description This command creates the context to configure generic RMON alarms and events.
Generic RMON alarms can be created on any SNMP object-ID that is valid for RMON monitoring (for
example, an integer-based datatype).
The configuration of an event controls the generation and notification of threshold crossing events
configured with the alarm command.
thresholds
Syntax thresholds
Context config>system
Description This command enables the context to configure monitoring thresholds.
Date and Time Commands
set-time
Syntax set-time [date] [time]
Context admin