System Management
Basic System Configuration Guide 459
Command Descriptions
Show Commands
The command outputs in the following sections are examples only; actual displays may differ
depending on supported functionality and user configuration.
alarm-contact-input
Syntax alarm-contact-input {alarm-contact-input-id | all} [detail]
Context show>system
Description This command displays the alarm contact input information.
Parameters alarm-contact-input-id — displays the alarm contact input information for a specific pin
Values 1 to 4
all — displays the alarm contact input information for all pins
detail — displays detailed alarm contact input information for one or all of the pins
Output The following table describes the system connections output fields.
Table 43: Alarm Contact Input Field Descriptions
Label Description
Alarm Contact Input
Power
Indicates if the +24VDC output pin (optionally used to provide power for
the alarm inputs) is enabled
Current State Indicate the configured administrative state of the input
Disabled = the alarm-contact-input is disabled (shutdown) and log events
will not be generated for changes to the input pin status
Enabled = the alarm-contact-input is enabled (no shutdown) and log
events will be generated for changes to the input pin status (as long as the
log events are not suppressed in event-control configuration)
Alarm Output Pin
Used
Indicates the configured severity of the associated CHASSIS log event
(for example, for pin 3: "configure log event-control" chassis"
tmnxSasAlarminput3StateChanged)
Alarm Raised Indicates if the input pin is 'triggered' or not
Last State Change Indicates when the input pin last changed state